Brother PJ-600/700 Series Command Reference 
19 
 
© 2015 Brother Industries, Ltd. All Rights Reserved. 
 
 
5.2.  Command details 
 
Name 
Invalid command 
Syntax 
NULL 
00 H   
Description  Skip 
If data transmission should be stopped midway, send the “initialize” command after 
sending the “invalid” command for the appropriate number of bytes to return to the 
receiving state, where the print buffer is cleared. 
 
Name 
Switch command mode 
Syntax 
ESC + i + a + {n1} 
1B H + 69 H + 61 H + {n1} 
Description  Switches between the machine's command modes. A machine that receives this 
command operates in the specified command mode until the machine is turned off. 
Definition of {n1}: 
0:ESC/P・Raster  (default) 
1: Maintenance Mode 
3:P-touch Template 
 
Name 
Initialize 
Syntax 
ESC + @   
1B H + 40 H   
Description  Initializes the print buffer. 
 
Name 
Status information request 
Syntax 
ESC + i + S 
1B H + 69 H + 53 H 
Description  Status information is transmitted. 
 
Name 
Set 2-ply mode 
Syntax 
ESC + 
~
 + p + {n1} + null 
1B H + 7E H + 70 H + {n1} + 00 H 
Description  Specifies whether or not the strobe time is extended and the print density is adjusted 
when 2-ply paper is used. 
Definition of {n1}: 
0:Disable (default) 
1:Enable