Samsung Freestanding Gas Ranges (NX58K9500 Series) Guía De Instalación

Descargar
Página de 120
English - 36
ADJUSTINg THE OVEN BURNER AIR ADJUSTMENT 
SHUTTERS
All oven burners have an air adjustment 
shutter. The purpose of the shutter is 
to regulate the flow of air to the flames. 
Properly adjusted flames should burn 
steadily with approximately 1-in of blue 
cone. The flames should never extend 
past the edge of the burner baffles. Even 
though these are preset at the factory, they 
should be checked and, if needed, adjusted 
periodically to ensure efficient operation.
To check and adjust the oven burner air adjustment 
shutters:
1.  Open the oven door.
2.  Remove the oven racks.
3.  Remove the oven floor.
4.  Press the Bake button, then the START/SET.
5.  After the oven has lit, visually check the flames coming out of the upper and 
lower burners. If adjustment is needed, carefully adjust the air adjustment 
shutters.
The shutters are located at the base of the burner manifolds near the back oven 
wall.
To adjust the shutter, loosen the locking screw 
and rotate the shutter towards the open or closed 
position as needed. If flames are lifting off the burner 
ports, gradually reduce the air shutter opening until 
the flames are stabilized.
If flames are too yellow and/or too large, gradually 
increase the air shutter opening until the flames have 
approximately a 1-in blue cone.
If the range is set up for natural gas, the flames should burn with no yellow 
tipping. If the range is set up for LP gas, small yellow tips at the end of the 
cones are normal.
After the flames are adjusted properly, shut off the 
oven, retighten the locking screws, replace the oven 
bottom and racks, and close the oven door.