Intel SR1695GPRX1AC Manual De Usuario

Descargar
Página de 83
Intel® Server System SR1695GPRX TPS 
 Front Panel Control and Indicators 
Revision 1.5 
43 
Intel order number: G11332-006 
7.2.2 
System Status LED 
Table 50. System Status LED Operation 
Color 
State 
Criticality 
Description 
Off 
N/A 
Not ready 
Power off or BMC initialization completes if no degraded, non-
critical, critical, or non-recoverable conditions exist after power cable 
plug in 
Green/
Amber 
Both Solid 
On 
Not ready 
Pre DC Power On – 15-20 second BMC Initialization when AC is 
applied to the server. The system will not POST until BMC 
initialization completes. 
Green 
Solid on 
Ok 
System ready 
Green Blink 
 
Degraded 
BIOS detected
1.  Unable to use all of the installed memory (more than one DIMM 
installed).
1
 
2.  In a mirrored configuration, when memory mirroring takes place 
and system loses memory redundancy. This is not covered by 
(2). 
1
 
3.  PCI Express* correctable link errors. 
Integrated BMC detected 
1.  One of redundant power supplies not present. 
2.  CPU disabled – if there are two CPUs and one CPU is disabled. 
3.  Fan alarm – Fan failure. Number of operational fans should be 
more than minimum number needed to cool the system. 
4.  Non-critical threshold crossed – Temperature, voltage, power 
nozzle, power gauge, and PROCHOT2 (Therm Ctrl) sensors. 
5. Battery 
failure. 
 
6.  Predictive failure when the system has redundant power 
supplies. 
Amber 
Blink 
Non-critical 
Non-fatal alarm – system is likely to fail 
BIOS Detected 
1.  In non-mirroring mode, if the threshold of ten correctable errors 
is crossed within the window.
1
 
2.  PCI Express* uncorrectable link errors. 
Integrated BMC Detected 
1.  Critical threshold crossed – Voltage, temperature, power nozzle, 
power gauge, and PROCHOT (Therm Ctrl) sensors. 
2.  VRD Hot asserted. 
3.  One of the redundant power supplies failed. 
4.  Minimum number of fans to cool the system are not present or 
have failed. 
Amber 
Solid on 
Critical, non-
recoverable 
Fatal alarm – system has failed or shutdown 
BIOS Detected 
1.  DIMM failure when there is one DIMM present and no good 
memory is present.
1
 
2.  Run-time memory uncorrectable error in non-redundant mode.
1
 
3.  CPU configuration error (for instance, processor stepping 
mismatch). 
Integrated BMC Detected 
1.  CPU CATERR signal asserted. 
2.  CPU 1 is missing.