Samsung Gourmet Vapour Technology™ Electric oven 73L Manual De Usuario

Descargar
Página de 92
12  English
Ins
tallation
Installation
Power connection
01 02 03
L
N
01 
BROWN or BLACK
02 
BLUE or WHITE
03 
YELLOW and GREEN
Plug the oven into an electrical socket. If 
a plug-type socket is not available due to 
allowable current limitations, use a multi-
pole isolator switch (with at least 3 mm 
spacing in-between) in order to meet safety 
regulations. Use a power cord of sufficient 
length that supports the specification H05 
RR-F or H05 VV-F, min. 1.5~2.5 mm².
Rated current(A)
Minimum cross-
sectional area
10 < A 
≤ 16
1.5 mm
2
16 < A 
≤ 25
2.5 mm
2
Check the output specifications on the label 
attached to the oven.
Open the rear cover of the oven using a 
screwdriver, and remove the screws on the 
cord clamp. Then, connect the power lines to 
the relevant connection terminals.
The ( )-terminal is designed for 
earthgrounding. First connect the yellow 
and green lines (earthgrounding), which 
must be longer than the others. If you use 
a plug-type socket, the plug must remain 
accessible after the oven is installed. 
Samsung is not responsible for accidents 
caused by missing or faulty earthgrounding.
WARNING
Do not step on or twist the wires during 
installation, and keep them away from heat-
emitting parts of the oven.
NV73J9770RS_SA_DG68-00613G-03_EN.indd   12
5/23/2016   2:17:18 PM