INSTALLATION AND EXTERNAL CONNECTION
Output Connection
Connect the 10-pin and 7-pin connectors of the controller as follows:
-  Door open (POWER FAIL SAFE) when the power is disconnected from the door lock (Door Relay)
Connect the relay COM line (gray with red stripes for locking the door) to DC +12V.
Connect the relay NC line (blue with white stripes for locking the door) to the plus(+) line of the door lock.
Connect the minus (-) line of the door lock to GND (-).
-  Door close (POWER FAIL SECURE) when the power is disconnected from the door lock (Door Relay)
Connect the relay COM line (gray with red stripes for locking the door) to DC +12V.
Connect the relay NO line (white with red stripes for locking the door) to the plus (+) line of the door lock.
Connect the minus (-) line of the door lock to GND (-).
- Alarm Connection (Alarm Relay)
Connect the relay COM (white for the alarm device) to DC +12V.
Connect the relay NO line (purple for the alarm device) to the plus (+) line of the alarm device.
Connect the minus (-) line of the alarm device to GND (-).
-  Chime Bell Connection (the chime bell operated by TTL-level signal must be installed in advance.)
Connect the chime bell line (brown with white stripes) of the controller to DC +5V.
Connect the GND line of the power supply unit to GND (-) of the chime bell.
Press 
ESC
to a0ctivate EthNeT chime bell.
1.
2.
3.
1.
2.
3.
1.
2.
3.
1.
2.
3.
X
Y
Z
[
\
]
^
_
`
lzj
lu{
W
iŒ““
zzhTzYWWW
EXIT
DOOR
LOCK
EXIT
CONTACT
AUX IN#1
CHIME
+12V
GND
GND
ALARM
RELAY
COM
DOOR
RELAY
COM
DOOR
RELAY
NO
ALARM
RELAY
NO
SIREN
GND
+12V
DC 12V
POWER
SUPPLY
PIR SENSOR
CHIME BELL
EXIT
BUTTON
DOOR
CONTACT
Cathode
Anode
1N4004~1N4007 or equiv.