Samsung SSA-S2000 Manual De Usuario

Descargar
Página de 51
English _ 31
I/O TIME SETUP
TO SPECIFY THE ALARM OUTPUT FOR AN INPUT ERROR OF THE 
DOOR CONTACT SENSOR
You can specify the output port and operation time if an error occurs from the Door Contact Sensor.
You must have specifi ed the operation time of the Door Contact Sensor. (Refer to “To specify the operation time of the 
Door Contact Sensor” on page 26.)
Present the Master Card to the device.
Press Button 
2
 and Button 
4
in sequence and press 
ENT
.
Refer to the output port table on page 29 and specify a desired output mode.
If you want the alarm relay alone to operate in normal and Secure modes 
in case of an error from the Door contact Sensor, select the <
5
2
buttons and press 
ENT
.
Enter the two-digit door relay output time and press 
ENT
.
Enter the two-digit alarm relay output time and press 
ENT
.
Enter the two-digit TTL relay output time and press 
ENT
.
You can specify a two-digit time from 00 to 99 seconds.
By default, all output times are set to “00”.
Other output ports that are not specifi ed for the output mode will not be activated. For instance, if you set the output 
mode to [5][2] and assign the operation time for each output device by following the steps 4, 5, and 6 above, only the 
alarm relay will operate.
TO SPECIFY THE ALARM OPERATION TIME FOR AUX 1
Present the Master Card to the device.
Press Button 
2
 and Button 
5
in sequence and press 
ENT
.
Refer to the output port table on page 29 and specify a desired output mode.
If you want the alarm relay alone to operate in normal and Secure modes in 
case of an input through the auxiliary port, select the <
5
2
> buttons 
and press 
ENT
.
Enter the two-digit door relay output time and press 
ENT
.
Enter the two-digit alarm relay output time and press 
ENT
.
Enter the two-digit TTL relay output time and press 
ENT
.
You can specify a two-digit time from 00 to 99 seconds.
By default, all output times are set to “00”.
Other output ports that are not specifi ed for the output mode will not be activated. For instance, if you set the output 
mode to [5][2] and assign the operation time for each output device by following the steps 4, 5, and 6 above, only the 
alarm relay will operate.
1.
2.
3.
4.
5.
6.

M
1.
2.
3.
4.
5.
6.

M
X
Y
Z
[
\
]
^
_
`
lzj
lu{
W
iŒ““
zzhTzYWWW
tˆš›Œ™Gjˆ
™‹
X
Y
Z
[
\
]
^
_
`
lzj
lu{
W
iŒ““
zzhTzYWWW
X
Y
Z
[
\
]
^
_
`
lzj
lu{
W
iŒ““
zzhTzYWWW
tˆš›Œ™Gjˆ™‹
X
Y
Z
[
\
]
^
_
`
lzj
lu{
W
iŒ““
zzhTzYWWW