SECTION 3 - FALSE ALARMS    
 
3.1  
Prevention of False Alarms 
 
Your memory capsule can be activated by two different methods.  
 
1. 
When the memory capsule is out of its bracket and in the water, the unit is transmitting.  
2. 
When the switch is moved to the ON position, in or out of the bracket, the unit is transmitting.  
 
There are a few precautions that should be taken to prevent false alarms. 
 
Do not transport memory capsule within 1 meter (3.3ft) of a magnetic source. 
Do not mount memory capsule within 1 meter (3.3ft) of a magnetic source. 
Do not store memory capsule outside of its bracket if it can get wet. 
Do not clean memory capsule with a water hose and brush. 
Do not mount memory capsule backwards in bracket.
 
 
3.2  
Reporting of False Alarms 
 
Should  there  be,  for  any  reason,  an  inadvertent  activation  or  false  alarm,  it  must  be  reported  to  the  nearest  SAR 
(search  and  rescue)  authorities.  The  information  that  should  be  reported  includes  the  memory  capsule  Unique 
Identifier  Number  (UIN),  Date,  Time,  duration  and  cause  of  activation,  as  well  as  location  of  memory  capsule  at  the 
time of activation. 
 
To Report False Alarms in the United States Contact any of the Following
 
Atlantic Ocean / Gulf of Mexico 
USCG Atlantic Area Command Center 
Tel: (757) 398-6390 
 
Pacific Ocean Area 
Tel: (510) 437-3700  
From Any Location 
 
 
USCG HQ Command Center 
Tel (800) 323-7233 
 
To Report False Alarms Worldwide Contact your National Authority. 
 
SECTION 4 - INSTALLATION / ASSEMBLY 
 
4.1 
Mounting Location 
 
The location selected must be sufficiently rigid to support the weight (approximately 9 lbs) of the total installation and at 
the  same  time  consider  vibration,  exposure  to  the  elements,  exposure  to  surrounding  hazards,  such  as  equipment 
movement,  doors  being  opened,  accidental  covering,  personnel  traffic,  etc.  The  memory  capsule  must  be  located 
no further than 50 meters (164 ft) from the S-VDR main unit.
 
 
Also  to  be  considered  in  selecting  a  location  for  installation  is  the  harmful  effect  that  certain  corrosive  vapors  might 
have on the memory capsule. Under no circumstances should a location be selected for installation where the memory 
capsule  would  be  jeopardized  by  any  foreign  articles  that  emit  corrosive  vapors  being  temporarily  or  permanently 
positioned during ―at sea‖ or ―in port‖ activities. 
 
Location  aboard  a  vessel  must  be  chosen  to  allow  the  memory  capsule  to  float  free  of  sinking  craft  and  as  high  as 
possible especially on smaller vessels. This will help ensure operation of the hydrostatic release unit in the event the 
vessel capsizes without sinking. 
 
Do not mount the memory capsule in the vicinity (3.3 ft.) of strong magnetic (such as loud speakers) or electrical (such 
as radar or high power radio transmitter) fields. The memory capsule should not be mounted closer than (3.3 ft) to a 
navigation compass.