ACR Electronics rcl-50 Manual De Usuario

Descargar
Página de 20
Y1-03-0141D
 
14
 
APPENDIX A- RCL-50B SPECIFICATIONS (with URC-102 
Controller)
 
Specification 
12V Unit 
24V Unit 
Mirror diameter 
4in (10.16cm) 
4in (10.16cm) 
Rated voltage (Volt) 
12- 16 VDC 
24- 31 VDC 
Rated current (A) 
Applicable lamp 
55W halogen  
(base 
–x511) 
H212V-55W 
70W halogen 
(base 
–x511) 
H2-37R-00624 
Peak beam candle power 
(candela) 
80,000 
80,000 
Beam spread (degrees) 
7
° 
7
° 
Elevation angle (degrees) 
Up 20
°, Down 20° 
Up 20
°, Down 20° 
Turning angle (degrees) 
360
° 
360
° 
Elevation speed 
6
° per second 
6
° per second 
Turning speed 
15
° per second 
15
° per second 
Weight 
6.16lbs (2.79 kg) 
6.16lbs (2.79 kg) 
Interconnect cable  
12ft (3.66 m) 
12ft (3.66 m) 
*All specifications are nominal values 
APPENDIX B- BULB REPLACEMENT PROCEDURE 
 
A  quartz-halogen  bulb  is  provided  with  your  RCL-50B.  If  the  bulb  should  need 
replacement, it can be ordered through an ACR dealer or through ACR Electronics. The 
part numbers are P/N 6002 for 12V units and P/N 6010 for 24V units.  
 
CAUTION: Failure to follow replacement instructions carefully can result in damage 
to bulb and/or light.  All part sales are final. 
 
To replace the lamps: 
1. Disconnect unit from power source and allow bulb to cool. 
2. Remove three screws holding the front flange and glass in place. 
3. To remove the old lamp bulb, grasp base of the lamp and pull straight out.  
WARNING: do not touch glass parabolic reflector or bulb with fingers or tools!  
4. Install the new lamp bulb using a soft clean cloth to avoid touching the bulb with your 
fingers. insert the lamp bulb pins into socket and press firmly in place. 
CAUTION: if the lamp bulb or reflector is accidentally touched, carefully 
clean with a soft rag and alcohol (isopropanol) before continuing. 
5. Replace the front flange and glass and install the three retaining screws. be sure the 
neoprene gasket is securely in place. 
6. Reconnect the unit to the power source.