Mounting 
The  Master  Controller  can  be  mounted  in  any  position  near  the 
searchlight  that  is  protected  from  the  weather.  Check  in  advance  that 
the  coax  cable  from  the  Point  Pad  and  the  wiring  harness  from  the 
searchlight  can  be  routed  to  this  location.  Mount  the  Master  Controller 
with  the  wires  and  coax  facing  down.  Use  an  appropriate  fastener  for 
your  mounting  location.  Use  a  sealant  in  fastener  holes  to  prevent 
moisture intrusion. 
 
General wiring scheme 
 
WARNING:  The  RCL-300  has  a  unique  wiring  scheme.  Special 
attention must be paid to the following chart.  
 
The  Master  Controller  is  supplied  with  an  in-line  fuse-holder  on  the 
Orange  power  lead.  Use  only  30  amp  fuses  in  this  fuse-holder.  See 
chart below for the Master Controller wiring diagram.  
 
WARNING:  Failure  to  follow  this  arrangement  may  damage 
components. 
 
 
Table 1 
 
 
WARNING: This wire MUST be fused with a 30 amp fuse in the 
Master Controller's in-line fuse-holder. 
 
 
Master 
Controller 
Wire 
Searchlight  
Cable Wire 
Wire Gauge 
(AWG) 
Power Source 
Lead 
Function 
Orange 
 
16 
+12 VDC or 
+24 VDC** 
URC-300 Power 
Blue 
 
16 
Ground 
URC-300 
Ground 
Yellow 
Yellow 
16 
 
Position Sensor 
Signal 
Green 
Green 
16 
 
Position Sensor 
Common 
Red 
Red 
16 
 
Up 
White 
White 
16 
 
Down 
Black 
Black 
16 
 
Right 
Brown 
Brown 
16 
 
Left 
White 
White 
12 
 
Lamp Power 
Black 
Black 
12 
 
Lamp Ground