Assigning Authorization Attributes
491
start-date
Date and time at which 
the user becomes eligible 
to access the network.
MSS does not 
authenticate the user 
unless the attempt to 
access the network occurs 
at or after the specified 
date and time, but before 
the end-date (if specified).
Date and time, in the following 
format:
YY/MM/DD-HH:MM
You can use start-date alone or with 
end-date. You also can use 
start-dateend-date, or both in 
conjunction with time-of-day.
time-of-day
(network access 
mode only)
Day(s) and time(s) 
during which the user 
is permitted to log into 
the network. 
After authorization, 
the user’s session can 
last until either the 
Time-Of-Day range or 
the Session-Timeout 
duration (if set) expires, 
whichever is shorter.
One of the following:
„
never — Access is always denied.
„
any — Access is always allowed.
„
al — Access is always allowed.
„
One or more ranges of values that 
consist of one of the following day 
designations (required), and a time 
range in hhmm-hhmm 4-digit 
24-hour format (optional):
mo — Monday
tu — Tuesday
we — Wednesday
th — Thursday
fr — Friday
sa — Saturday
su — Sunday
wk — Any day between Monday 
and Friday
Separate values or a series of ranges 
(except time ranges) with commas (,) 
or a vertical bar (|). Do not use spaces.
The maximum number of characters is 253.
For example, to allow access only on 
Tuesdays and Thursdays between 
10 a.m. and 4 p.m., specify the 
following: 
time-of-day tu1000-1600,th1000-1600
To allow access only on weekdays 
between 9 a.m and 5 p.m., and on 
Saturdays from 10 p.m. until 2 a.m., 
specify the following: 
time-of-day wk0900-1700,sa2200-0200
Note:
 You can use time-of-day in 
conjunction with start-date
end-date, or both.
Table 43   Authentication Attributes for Local Users (continued)
Attribute
Description
Valid Value(s)