PECIFICATIONS
This appendix lists the specifications for the SuperStack II Hub 1000 SX.
Physical Dimensions
Environmental Operating Ranges
Power Requirements
Height:
4.37 cm (1.72 in.)
Width:
43.94 cm (17.3 in.)
Depth: 
30.48 cm (12 in.)
Weight:
5.5 kg (12 lb)
Operating temperature: 0˚ to 50 ˚C (32˚ to 122 ˚F)
Storage temperature:
–30˚ to 60 ˚C (–22˚ to 140 ˚F)
Operating humidity:
10% to 90% relative humidity, noncondensing
Storage humidity:
10% to 95% relative humidity, noncondensing
Electrostatic discharge:
Does not exceed 25 kV
Operating altitude:
–300 to 3000 meters (–296 to 9840 ft)
AC input voltage:
90–264 V; 115–230 V nominal
Input frequency range: 47–63 Hz, single phase AC
Inrush current:
40 A peak maximum at cold start for half cycle 
at any rated input voltage; no damage to the 
supply from repeated on/off/on cycles under hot 
or cold conditions
AC input isolation:
Between primary and secondary circuits: 3000 V
Between primary circuit and chassis: 1500 V
Power consumption:
65 W maximum
Heat output:
90 BTU/hr
Fuse:
Fast-blow, 250 VAC, 3.15 A, high 
breaking capacity