Testing
H2TU-C-231 List 2
January 9, 2002
53
T
ESTING WITH
H2TU-R BERT G
ENERATOR
The H2TU-R BERT Generator screen allows transmission of a test signal from the H2TU-R towards either the
network (NET) or customer (CPE). Bit error rates are calculated and display on the Monitor screen.
1
Press
to logon remotely, then press
to select the Config menu.
2
Use the
and
arrow keys to select BERT Generator, then press
.
3
Use the arrow keys to select an option, then press the
to cycle through the settings. Refer to
for a list of BERT Generator option settings.
4
Press
to activate your choice.
5
To view BERT status, press
twice, then, using the
arrow key to select the Monitor menu, press
.
6
Press
to return to the H2TU-C logon screen. You can exit the status screen while signal generation is active.
Figure 30.
H2TU-R BERT Generator Screen
The test pattern is sent out either from the line unit towards the network (toward NET) or from
the remote unit towards the customer (toward CPE). Both test payloads must be looped back so
they can be returned to the unit for BER detection. BER detection is performed in the line unit
for both switch settings.
Tests done towards the NET must be looped at some point external to the higher circuit. Tests
done towards the CPE can either be looped back at some external point beyond the remote unit,
or they can be looped back internally by a higher loopback, such as NREM. The test payload,
for the CPE direction, also passes back and forth over the HDSL2 link to the H2TU-C before it is
analyzed for errors.
R
C
ENTER
SPACEBAR
ENTER
ESC
ENTER
R
Monitor
Perf ormance
Event Log
Config
Inventory
Report
Rlogon
Help
+------- ---------------+
| Standa rd Options ->
|
| ADC Op tions
->
|
| Signal Generator ->
|
|
BERT Generator
->
|
+------- -------------------------- -----+
| BERT S ignal Generator
:
ENA
|
| BERT S ignal Pattern
: 1 in 7
|
| BERT S ignal Linecode
: AMI
|
| BERT S ignal Direction
: NET onl y
|
| BERT I nterval
: Continu ous
|
+------- -------------------------- -----+
Use <Spacebar > to cycle through option s ettings and <Enter> to act ivate
ID: xxxx—-xx xx—-xxxx--xxxx
09/01/2001 12:30:01
H2TU-R
Sy stem: OK
___