HP designjet l65500 Manuales De Servicio

Descargar
Página de 179
Te
sts
, U
tilities
 & Ca
lib
ra
tio
ns
 Service Tests, Utilities & Calibrations
441
Calculating the results of the test
The values that were displayed at the end of the procedure can now be used to calculate if any shims 
need to be installed in the Printhead Cleaning Assembly and where they should go at the front or rear of 
the assembly.
Subtract the value in millimeters of the Y/M printheads from the value of the C/K printheads. In the 
example here this would be:
If the resulting figure is positive, the shim(s) need to be installed on the front side of the Printhead 
Cleaning Assembly.
If the resulting figure is negative, the shim(s) need to be installed on the rear side of the Printhead 
Cleaning Assembly.
The table below shows the range of values in millimeters and the applicable number of shims required 
(0,1 or 2). In the example shown above the calculation came to ‘-0.6’, this would mean that 1 shim is 
required on the High side and the front.
Installing the shims
The following procedure describes how to install the shims into the mechanism.
1.
Remove the Wide Wipe Assembly.
2.
Loosen the two screws on the side, either at the front (if the value was positive) or at the rear (if the value 
was negative). Do not remove the screws.
A
B
A-B=X
Note: The shim height/thickness is 0.6mm