Hardware options installation 46 
mirroring protection) because of a single uncorrectable error. Mirroring protection is not lost because of 
transient and soft uncorrectable errors, resulting in systems that maintain mirroring protection (and thus 
improved uptime) unless there is a failure of both branches. 
Mirrored memory FBDIMM configuration requirements (in addition to general configuration requirements): 
 
Banks A and B must be fully populated. 
 
Bank A and bank B must contain FBDIMMs with identical part numbers. If installed, bank C and 
bank D must also contain FBDIMMs with identical part numbers. 
When using mirrored memory mode, FBDIMMs must be populated as specified in the following table: 
 
Configuration Bank 
1A and 3A 
Bank B 
5B and 7B 
Bank C 
2C and 4C 
Bank D 
6D and 8D 
1 X X — — 
2 X X X X 
 
After installing FBDIMMs, use RBSU to configure the system for mirrored memory support ("
mirrored memory
" on page 
63
). 
 
Installing FBDIMMs 
  
 
CAUTION:
  To avoid damage to the hard drives, memory, and other system components, the 
air baffle, drive blanks, and access panel must be installed when the server is powered up. 
  
1. 
Power down the server (on page 
2. 
Extend the server from the rack (on page 
3. 
Remove the access panel (on page 
). 
4. 
Move the hard drive cables. 
5. 
Remove the air baffle. 
6. 
Open the FBDIMM slot latches. 
7. 
Install the FBDIMM. 
 
8. 
Install the air baffle. 
9.