CANON  Digital Galvano Scanner System  GM-1000 Series 
Users Manual 1.20 
 
 
 
  
27
(Target Position Data)  DAT (AXIS1), DAT (AXIS 2) 
It is possible to switch the length of data used as target position data from the DAT (AXIS1), DAT (AXIS 
2) 20 bit (every 100 kHz) signals. Please set appropriately to match the signal specifications of the 
scanner controller that outputs a high-speed serial communication signal, and other output equipment. 
 
Note: The length of data input in the GC-201 is always 20 bit (every 100 kHz). The bits of the target 
position data that get used and sent are switched from within 20 bit data. 
When there is a big difference in the target position specified in the high-speed serial communication, 
and the actual operation position, it is possible this parameter setting is incorrect. Please verify. 
 
The data length of the target position data by the high-speed serial communication can be changed by 
two following parameters. 
 
(Target position data length) 
Can be changed by 16 bit – 20 bit. 
Parameter ID 
DATA 
67 
16: 16bit  Data * 
17: 17bit  Data 
18: 18bit  Data 
19: 19bit  Data 
20: 20bit  Data 
(Data position) 
The least significant bit position of the target position data of high-speed serial communication 20bit 
data can be set by following parameter. The specified number of bits is shifted right, making the target 
position data. 
 
Parameter ID 
DATA 
68 
0: 0bit  position 
1: 1bit  position * 
2: 2bit  position 
3: 3bit  position 
4: 4bit  position 
With the default settings at shipping, the setting is * (16 bit position data length, data least significant bit 1 
bit position). This communication specification is compatible with XY2-100. When using the scanner 
controller of XY2-100 specifications, please use this setting.