Canon mf3220, mf3228, mf3240 Manuales De Servicio

Descargar
Página de 120
Chapter 5  
5-2
0030
Can't receive any signal within 6 sec. At phase D.
0031
Received incorrect signal at phase D (not EOP, MPS, EOM, DCN, PPS_Q, PPS_Q,etc)
0032
Can't receive carrier within 6 sec after sending MCF or RTP, RTN signal
0033
Received DCN signal at ohase D within pages (not last page).
0039
In non_ECM mode, when machine alredy received the data dosen't receive 13.1 seconds
001F
Can't detect any G3 signal within 35 sec after sending DTC signal
003F
Remote side TSI not define in machine one touch or speed dial directory
0040
Can't receive carrier within 6 sec. after sending CTR.
0041
Can't receive carrier within 6 sec. after sending PPR.
0042
Can't receive correct signal after sending RNR signal
0043
Receive incorrect signal at phase D in ECM mode.
0044
Can't receive carrier/FSK signal within 6 sec. After sending MCF. ln ECM mode.
0047
Can't receive correct signal or DCN received after sending ERR signal.
0048
Can't receive correct signal after receive PPS_PRI_Q
004B
Can't detect correct FSK signal even through detected FSK tone within 6 sec.
004C
Handshake fail during re-train or between page in V34 Rx.
004E
Receive DCN signal after sending DIS in V.34.
004F
Remote side disconnected after sending ANSam in V.8 phase.
0050
Can't receive any correct signal after detected CJ signal in V.8 phase.
0051
Can't receive phase 3 signal after phase 2 within 20 seconds in V.34.
0053
Modem disconnect after phase 4 in V.34.
0054
Remote side disconnect after phase 4 in V.8
0055
Receive incorrect signal after sending DIS signal in V.34
0056
Modem disconnect after sending CFR in V.34
0058
Can't detect image signal within 6 sec after modem enter to primary phase in V.34
005A
Modem cannot  detect any correct ECM frame with 3 minutes in phase C.
005B
Modem can't detect control channel with 12 sec in phase C
005C
Detect busy tone within control channel after phase C.
005D
Modem can't detect any correct ECM frame with 12 sec in phase C.
005E
Can't detect control channel signal  after received RCP frame within 6 sec
005F
Can't detect silence after sending JM signal for polling TX function.
0060
There are no any bullietin files to be polled in V.34.
0061
Machine cannot detect V.21 or V.8 signal with 35 sec.
0062
Modem disconnect in phase D after our side sending out flags sequence in control channel.
0063
Can't receive any flag sequence in control channel within 25 sec in phase D.
0064
Can't detect any control channel signal in phase D within 60 sec even through energy still on the 
line.
0065
Can't detect any control channel signal within 60 sec after detect sillence in phase D.
0066
Can't receive T.30 signal or carrier after sending CFR in V.34.
0069
Capability no match paper size after received is DCS signal.
0070
User press stop key within receiving.
0071
Memory full within receiving.
0080
Can't detect any G3 signal within 35 sec. specified by ITU-T in phase B.
0081
Received DTC signal in transmission phase.
0082
Transmitting unit receives a signal other than DIS or DTC. And DCN in phase B.
0083
Detected FSK signal, but Can't receive any signal within 35 sec.
0084
Detect DCN signal in phase B.
0085
Transmitting unit sending DCS 3 times consecutively, but each time responds with DIS/DTC
0086
Detected responds signal other than DTC,DIS,FTT,DCN or CFR after sending DCS.
0087
Training attempt has failed because speed unit can't adjust to low lower speed.
0088
Received DCN signal after sending out DCS signal
008B
Receivers  protcol of DIS is received, but it is not compatible with our machine.
008C
Remote side or our side not support capability.
008D
Receivers protocol of DIS is received, but remote side can't receive document temporary, may 
because by run out of paper or other reason.
008F
Modem not ready to received V.34 data within 6 sec after received CFR signal.
0090
Called side document not ready for our polling.
0091
Can't receive any commabd after send DCN signal 3 times consecutively
0093
Received DCN signal after sending out DCN signal
0094
Time out during transmit ECM frame or RCP command.
0095
Wrong ID number
0096
SUBADDRESS/PASSWORD capability not match in polling Rx mode.
009A
Can't detect any signal after sending CI signal.
009D
Remote side hang up before V.34 modem enter phase 2 state in V.34 polling Rx.
009E
Manual Tx over 15 minutes whin in phase C by non-ECM mode.
00A0
User stop or cancel transmission job.
00A1
Document JAM within transmission
Error Code
Description