Canon mf3220, mf3228, mf3240 Manuales De Servicio

Descargar
Página de 120
Chapter 5  
5-6
5.4.2.4.2 Details of Bit 3
0012-7150
The document reading width can be selected.
When selecting the "LTR" size, a "LTR" size document can be read in the
"LTR" width (214 mm).
5.4.2.5 SSSW-SW30
5.4.2.5.1 List of Functions
0012-7135
T-5-10
5.4.2.5.2 Details of Bit 7 and Bit 8
0012-7136
Use it to set the length of a pause; the following will be ture depending on
the combination of bit 7 and bit 8:
T-5-11
5.4.2.6 SSSW-SW33
5.4.2.6.1 List of Functions
0012-7201
T-5-12
5.4.2.6.2 Details of Bit 4 and Bit 5
0012-7202
Selects whether the NL equalizer Transmission and reception is on or off. If
frequent errors occur during transmission and reception because of line con-
ditions, select the NL equalizer ON.
5.4.2.7 SSSW-SW37
5.4.2.7.1 List of Functions
0012-7137
T-5-13
5.4.2.7.2 Details of Bit 1 through Bit 6
0012-7138
Select the maximum baud rate for V.34 transmission: 3429, 3200, 3000,
2800, and 2400.
The following will be ture depending on the combination of bit 1 through bit
6
at time of transmission
T-5-14
at time of reception
T-5-15
5
Not used
-
-
6
Not used
-
-
7
Not used
-
-
8
Not used
-
-
Bit
Function
1
0
Bit
Function
1
0
1
Not used
-
-
2
Not used
-
-
3
Not used
-
-
4
Not used
-
-
5
Not used
-
-
6
Not used
-
-
7
Pause time
1*
0
8
Pause time
1
0*
(Bit7, Bit8)= (0, 0) 2.0 sec.
(1, 0) 2.5 sec.
(0, 1) 3.0 sec.
(1, 1) 3.5 sec.
Bit
Function
1
0
1
Not used
-
-
2
Not used
-
-
3
Not used
-
-
4
NL Equalize (Transmission)
ON
OFF
5
NL Equalize (Reception)
ON
OFF
6
Not used
-
-
7
Not used
-
-
8
Not used
-
-
Bit
Function
1
0
1
V.34 Baud rate (TX)
1
0*
2
V.34 Baud rate (TX)
1
0*
3
V.34 Baud rate (TX)
1
0*
4
V.34 Baud rate (RX)
1
0*
5
V.34 Baud rate (RX)
1
0*
6
V.34 Baud rate (RX)
1
0*
7
Not used
-
-
8
Not used
-
-
(Bit1, Bit2, Bit3)= (0, 0, 0) 3429
(1, 0, 0) 3200
(0, 1, 0) 3000
(1, 1, 0) 2800
(0, 0, 1) 2400
(Bit4, Bit5, Bit6)= (0, 0, 0) 3429
(1, 0, 0) 3200
(0, 1, 0) 3000
(1, 1, 0) 2800
(0, 0, 1) 2400