Test Environment
This product was tested in BLI’s 929-square-metre U.S. test lab, in an environment monitored by an Extech RH S20 Digital 
RH/Temperature Recorder and Honeywell Model 61 Seven-Day Temperature/Relative Humidity Chart Recorder. All products 
lab tested by BLI are powered by dedicated circuits that are protected by ESP (Electronic Systems Protection, Inc.) surge 
protectors to prevent transient power and communication disturbances from impacting equipment under test.
Test Equipment
BLI’s dedicated test network, consisting of Windows 2003 servers, Windows XP workstations, 10/100BaseTX network 
switches and CAT5 cabling.
Test Duration
Products are tested for two months, a portion of which consists of a durability test during which the product is run at half of 
its manufacturer-rated maximum monthly volume, with varying daily test volumes designed to replicate real-world use over 
an eight-hour workday. This variable schedule includes a mix of various-size documents, simplex and duplex modes, and a 
mix of short, moderate and long run lengths, and on/off cycles, throughout the day.
Tested Configuration
Samsung CLP-670ND base unit, plus optional 512-MB memory upgrade and 500-sheet drawer.
Test Procedures
The test methods and procedures employed by BLI in its lab testing include BLI’s proprietary procedures and industry-
standard test procedures, which include a BLI-developed variation of ASTM’s 1318-90 Test Method for Determination of 
Productivity using Electrostatic Copy Machines. In addition to a number of proprietary test documents, BLI uses an industry-
standard KATUN test original for evaluating black image quality and test suites from Quality Logic to evaluate applications 
compatibility. In addition to a visual observation under a Graphiclite D5000 Standard Viewer, colour print quality is tested 
using a colour test target, which is read using the X-Rite Eye-One/iO Colour Spectrophotometer, and samples are analysed 
using the CIE XY Chromaticity Diagram. In addition, density of black and colour output is measured using an X-Rite 500 
Series Densitometer. Georgia-Pacific Spectrum Multi-Use Paper is used in the tests, 10 percent of which is recycled paper 
containing 30 percent post-consumer content. Image quality is tested using Georgia-Pacific Printing Paper.
SUPPORTiNG TeST DaTa
BUyeRS LaBORaTORy 
    
North America  •  Europe  •  Asia
Michael Danziger
CEO
Mark Lerch
COO
Anthony F. Polifrone
Managing Director
Daria M. Hoffman
Managing Editor
John Donnelly
Managing Director—International
Pete Emory
Manager of Laboratory Testing
David Sweetnam
European Lab and Research Manager
Jon Bees
Director of Strategic Marketing Products
Buyers Laboratory Inc.
info@buyerslab.com
BLI International (UK) Ltd.
bliEurope@buyerslab.com
BLI International Ltd.
bliAsia@buyerslab.com
BuyersLab.com
©2010  Buyers  Laboratory  Inc.  Reproduced  by  permission  of  Buyers  Laboratory  Inc.  Any  duplication  of  this  report  without  the  written 
permission  of  Buyers  Laboratory,  is  unlawful  and  violators  will  be  prosecuted.  To  purchase  reprints,  contact  BLI  at  at  info@buyerslab.com.