ting
Alarm messages and associated directions
Alarm message on monitor screen
(Cause)
Direction
Alarm message in time 
counter display
A cleaning tape has been inserted.
The tape will automatically be ejected after cleaning is 
completed.
Cleaning Tp!
A non-standard signal is being used for 
input video.
Use a standard signal.
VIN NON-STD
A non-standard ref. signal is being used 
for REF. VIDEO.
Use a standard signal.
REF NON-STD
Abnormal settings selected in setup 
menu.
Correct the setup menu settings. Contact your Sony 
dealer if this alarm message appears again after 
making corrections.
ILL. SETUP!
Audio mixing mode cannot be changed 
during recording.
REC mode!
Audio not editable on this tape.
Use a tape recorded in 2-channel/48 kHz or 
4-channel/32 kHz mode.
2CH/32kHz!
Fs 44.1kHz!
Use a tape having audio signals recorded in locked 
mode.
UNLOCK mode
Audio REC mode selection different from 
audio on tape.
Select the same audio recording mode as that of the 
tape.
A mode err
Audio REC (recording) mode cannot be 
changed during recording.
REC mode!
Cassette adaptor not usable.
Use a tape without cassette adaptor.
Adaptor!
Counter mode is selected.
Use the COUNTER SELECT button to light the TC or 
U-BIT time data type indicator in the display section.
CNT mode!
Input selection cannot be changed in 
REC (recording) mode.
REC mode!
Input signal does not conform to 
DVCAM/DV format.
Unknown Sig
Input signal is 625/50. (For DSR-1500)
625/50 sig! (For DSR-
1500A)
Input signal is 525/60. (For DSR-
1500AP)
525/60 sig! (For DSR-
1500AP)
Input video is not detected.
Check the VIDEO indicator in the INPUT signal 
display section and supply an appropriate video 
signal.
No INPUT!
Input video signal does not synchronize 
with REF. VIDEO signal.
Use a reference video signal.
ILL. REF!
Moisture has been detected.
Keep the power on and wait until this alarm message 
disappears.
HUMID!
No cassette in VTR.
Load a cassette.
No Cass.!
Non DVCAM/DV(SP) format source.
No DVCAM/DV
Rec inhibit mode is selected.
Set the REC INHIBIT menu item 
OFF.
REC INHI.!
Record inhibit plug on the cassette is set 
to inhibit.
Set the REC/SAVE switch on the cassette to REC.
REC INHI.!
Remote mode is selected.
Set the LOCAL/REMOTE switch to LOCAL.
REMOTE!
Select  DVCAM recording format.
Set the REC FORMAT menu item
 to 
DVCAM.
Not DVCAM!
Tape cannot be replayed.
Use a tape recorded in 525/60 format. (For DSR-
1500A)
625/50 Tape (For DSR-
1500A)
Use a tape recorded in 625/50 format. (For DSR-
1500AP)
525/60 Tape (For DSR-
1500AP)