Kurth Electronic CCTS-02 0.49616 Prospecto
Los códigos de productos
0.49616
Cable Conductor Test Set
Splicers Head Set
CCTS02
CCTS02 cable conductor test set is used in a set of two.
Two (or more) technicians are able to setup a communi-
cations path over dead lines up to 3000 Ohms or more.
Be carefull - only on dry telephone lines it is possible to
setup communications. Don`t use it on life power lines.
Two (or more) technicians are able to setup a communi-
cations path over dead lines up to 3000 Ohms or more.
Be carefull - only on dry telephone lines it is possible to
setup communications. Don`t use it on life power lines.
After a new cable installation or after repair a cable in
service, the cable has to be tested for common faults
like pair reversals, opens, shorts or ground faults.
These tests are fast and easy to handle with CCTS02.
service, the cable has to be tested for common faults
like pair reversals, opens, shorts or ground faults.
These tests are fast and easy to handle with CCTS02.
To establish voice communication over a dead pair, plug
To protect the units they are stored in a
the headset into the jack on the left side. Turn CCTS02
pouch of strong cordura.
on. The red ON LED indicates that the unit is on.
Connect the black talk leads to a empty pair on the
cable. There is no special polarity. If both units are
connected to the same pair, voice communication is
Connect the black talk leads to a empty pair on the
cable. There is no special polarity. If both units are
connected to the same pair, voice communication is
CCTS02 comes with solid test leads with 4mm banana
established. To test wires, one unit has to be in RX-
plugs, solid clips and test tip. There is a lightweight and
mode and one in TX-mode.
noise compensated headset and a special headset to
use in conjunction with a hard hat. A heavy headset with
completely closed receivers for very noisy areas is
optional available.
use in conjunction with a hard hat. A heavy headset with
completely closed receivers for very noisy areas is
optional available.
If the pair is in service, it is sometimes, especially if xDSL
or ISDN service is on the line, impossible to find a single
wire Tip (A) or Ring (B). This because the impedance
between the wires of a pair is very low ( i.e. 120 Ohms).
CCTS02 Microprocessor technology tunes the unit to
the resistance of one wire. After it is possible to find
wires with low resistance differences to the correspon-
ding wire in a pair.
This saves time - no need for open the line on the MDF.
or ISDN service is on the line, impossible to find a single
wire Tip (A) or Ring (B). This because the impedance
between the wires of a pair is very low ( i.e. 120 Ohms).
CCTS02 Microprocessor technology tunes the unit to
the resistance of one wire. After it is possible to find
wires with low resistance differences to the correspon-
ding wire in a pair.
This saves time - no need for open the line on the MDF.
The electronic circuits are protected by a solid housing
made of ABS.
made of ABS.
The battery compartment is
separated and closed by captive screws. CCTS02
needs a standart 9 Volt alkaline battery.
needs a standart 9 Volt alkaline battery.
The test tone is audible in both headsets when the red
test lead is in contact with the same conductor under
test.
test lead is in contact with the same conductor under
test.
0
8
/2
0
0
6
P
ro
d
u
c
t
d
e
s
ig
n
a
n
d
s
p
e
c
if
ic
a
ti
o
n
s
s
u
b
je
c
t
to
c
h
a
n
g
e
w
it
h
o
u
t
n
o
ti
c
e
.
A
ll
tr
a
d
e
m
a
rk
s
b
e
lo
n
g
t
o
t
h
e
ir
r
e
s
p
e
c
ti
v
e
c
o
m
p
a
n
ie
s
.
®
Set Contains:
CCTS02
3 Test Leads
2 Precission Clips
1 Needle Tip
1 Headset
1 Headset for Hard Hat use
1 Pouch
CCTS02
3 Test Leads
2 Precission Clips
1 Needle Tip
1 Headset
1 Headset for Hard Hat use
1 Pouch
Lightweight and solid test set
indispensable for:
indispensable for:
ü Setup
ü fault tracking
ü maintenance
ü usefull also on powered telecom
ü fault tracking
ü maintenance
ü usefull also on powered telecom
lines
ü line resistance up to 2000 Ohm
ü Microprocessor for tuning on life
ü Microprocessor for tuning on life
lines
ü xDSL and Data Safe
ü Over Voltage Protected
ü Over Voltage Protected
checks for:
ü reversals
ü split pair
ü short
ü open
ü ground fault
ü reversals
ü split pair
ü short
ü open
ü ground fault