Sony HDW-S280 Manual De Usuario
12
Front Panel
C
h
h
ap
te
te
r 2
N
a
a
m
e
s
a
n
d
F
u
nc
tion
s
tion
s
of
P
a
rt
s
e R/P LEVEL CTL switch
VAR: Enables adjustment with the PB LEVEL adjustment
VAR: Enables adjustment with the PB LEVEL adjustment
knobs or REC LEVEL adjustment knobs while you
view the audio level meter in E-E mode.
view the audio level meter in E-E mode.
PRESET: Presets to fixed levels. Levels cannot be
adjusted with the PB LEVEL adjustment knobs or
REC LEVEL adjustment knobs.
REC LEVEL adjustment knobs.
For Switching to E-E mode, see “ To monitor in E-E
mode” on page 14.
mode” on page 14.
f LEVEL adjustment knob
Adjusts the volume of the headphones connected to the
PHONES jack.
Adjusts the volume of the headphones connected to the
PHONES jack.
g PHONES (headphones) jack
Connect headphones.
Connect headphones.
h REC INHI switch and indicator
ON: Recording on the tape is inhibited, regardless of the
ON: Recording on the tape is inhibited, regardless of the
state of the cassette’s erasure prevention plug. The
REC INHI indicator lights.
REC INHI indicator lights.
OFF: Recording on the tape is enabled when the cassette’s
erasure prevention plug is set to the original position.
i KEY INHI switch
When this switch is set to ON, the functions of the buttons
selected with setup menu item 118 are inhibited.
When this switch is set to ON, the functions of the buttons
selected with setup menu item 118 are inhibited.
For details on setup menu item 118, see page 64.
j Cassette compartment
Insert a cassette here.
Insert a cassette here.
k EJECT button
Press to eject the cassette. The cassette mark in the display
window flashes while the cassette is being ejected.
Press to eject the cassette. The cassette mark in the display
window flashes while the cassette is being ejected.
l REMOTE button
Selects the operation mode of this unit.
When the button is not lit, the unit is controlled from the
front panel of this unit. Normally use this status.
When the button has been pressed and is lit, this unit is
controlled from the device connected to the REMOTE 9P
connector. In this case, all VTR operations using this unit’s
front panel are disabled except those of the STOP and
EJECT buttons.
When two HDW-S280 units are connected, press this
button on the player VTR to make it lit.
Selects the operation mode of this unit.
When the button is not lit, the unit is controlled from the
front panel of this unit. Normally use this status.
When the button has been pressed and is lit, this unit is
controlled from the device connected to the REMOTE 9P
connector. In this case, all VTR operations using this unit’s
front panel are disabled except those of the STOP and
EJECT buttons.
When two HDW-S280 units are connected, press this
button on the player VTR to make it lit.
You can determine which tape transport buttons on the
front panel are to be enabled when the REMOTE button is
lit with setup menu item 006.
front panel are to be enabled when the REMOTE button is
lit with setup menu item 006.
For details on setup menu item 006, see page 61.
2-1-1 Menu Operation Section
a Function buttons
Select and set menu items displayed in the display window.
Select and set menu items displayed in the display window.
b Display window
Displays menus, audio level meters, and data such as time
data or meta-data. The DISPLAY button let you switch to
the video monitor display.
Displays menus, audio level meters, and data such as time
data or meta-data. The DISPLAY button let you switch to
the video monitor display.
For details, see “2-1-3 Display Window” on page 14.
c MENU button
Displays a setup menu item in the time data display area of
the display window.
Displays a setup menu item in the time data display area of
the display window.
For details on the setup menu operations, see “9-2 Setup
Menu Operations” on page 58.
Menu Operations” on page 58.
d DISPLAY button
Switches the operation display to the video monitor display
and vice versa.
Switches the operation display to the video monitor display
and vice versa.
e RESET button
Resets the CTL data displayed in the display window or the
initial value of the timecode generator.
Resets the CTL data displayed in the display window or the
initial value of the timecode generator.
f SHIFT button
Switches between functions for any button with two
functions.
Switches between functions for any button with two
functions.
REC LEVEL 2
Channel 2
Channel 4
PB LEVEL 1
Channel 3
Channel 1
PB LEVEL 2
Channel 4
Channel 2
Adjustment knob
Recording
channel
channel
Playback
channel
channel
CHARACTR
ON
PB/EE
PB
CONFI
ENABLE
CTL/TC
TC
ASSEMBLE
OFF
TCG SET
HOME
LTC
DF VITC LTC EXT-LTC R-RUN REM:00
M
0
–10
–20
–30
–30
–40
1
CH1 IN :
CH2 IN :
CH2 IN :
OUT :
MONI L :
MONI R :
MONI R :
–60
INPUT : ANA
–4
HD
COND
P ROLL
D-STOP
BANK 2
DOLBY NR
+4
1
2
1
2
SDI ASMBL CONFI ON RECORDER
59.94i
EMPH
2
EMPH
0
–10
–20
–30
–30
–40
3
EMPH
4
EMPH
00:00:00:00.
SHIFT
MENU
DISPLAY
RESET
PAGE
HOME
MULTI CONTROL
PUSH
PITCH CTL
1
Function buttons
2
Display window
3
MENU button
7
PAGE/HOME button
6
SHIFT button
4
DISPLAY
button
button
5
RESET
button
button
8
MULTI CONTROL knob