Recording Images in Memory — Image memory Menu
81
Alarm recording Tab — Setting the 
Image memory function when 
detecting the alarm
You can set to record an image and audio file to the 
memory linked with an external sensor input or built-in 
detection functions.
Alarm recording
Select On to configure the settings for recording image 
and audio files linked with alarm detection.
Image file name
Type the file name you want to assign to the image(s) to 
be recorded. You can use up to 10 alphanumeric 
characters, - (hyphen) and _ (underscore) for naming.
Suffix
Select a suffix to be added to the file name.
Date & time: The Date & time suffix is added to the 
image file name.
The Date & time suffix consists of the year (2 digits), 
month (2 digits), date (2 digits), hour (2 digits), 
minute (2 digits), second (2 digits) and sequential 
number (2 digits), thus adding a 14-digit number to 
the image file name.
Sequence number: A sequential number of 10 digits 
between 0000000001 and 4294967295 and an 
sequential 2 - digit number is added to the image file 
name.
Tip
A sequential number added to Date & time and 
Sequence number is used to identify individual files 
created with consecutive alarm events.
Sequence number clear
Click Clear to reset the Sequence number suffix to 1.
Alarm
Select the alarm to be linked with the recording of image 
and audio files.
Sensor input 1: The external sensor that is connected to 
sensor input of the camera I/O port.
Camera tampering detection: An alarm that is 
triggered if the camera detects tampering, such as 
direction shifting or spray.
VMF: An alarm of the VMF detection function.
Motion detection: The alarm by the motion detection 
function.
Click Detection, and the Motion detection menu is 
displayed to allow you to set the motion detection 
function (page 91).
Audio detection: Click Detection, and the audio 
detection menu is displayed to allow you to set the 
audio detection function (page 91).
Note
When a preset position is set in the menu of Preset 
Position-Alarm linked position
, the alarm is invalid if 
the camera is moved to a preset position.
Effective period
Set the period during which alarm detection is effective.
Always: Alarm detection is always effective.
Schedule: You can specify the period during which 
alarm detection is effective.
Click Schedule to display the setting menu for the 
effective period. (“Setting the Schedule — Schedule 
Menu” on page 90)
Alarm buffer
Select Use alarm buffer when you record the image/
audio at a specific time before or after alarm detection 
(pre-alarm, post-alarm).
If you do not select the alarm buffer, only the image at 
the moment of alarm detection is recorded.
Click Alarm buffer to display the Alarm buffer menu.
For details, see “Setting the Alarm Buffer — Alarm 
buffer Menu” on page 90
.
Note
When Edge Storage is enabled, the Alarm buffer is not 
available.
OK/Cancel