Temperature and Humidity Range
Temperature
Operating
5˚C to 40˚C (
T<10˚C/h) (41˚F to 104˚F (
T<18˚F/h))
Non-operating (mech.)
– 40˚C to 70˚C (
T<20˚C/h) (– 40˚F to 158˚F (
T<36˚F/h))
Non-operating (tape)
– 40˚C to 45˚C (
T<20˚C/h) (– 40˚F to 113˚F (
T<36˚F/h))
Humidity
Operating
20 to 80% RH, non-condensing
Maximum wet bulb temperature = 26˚C (78.8˚F)
Non-operating (mech.)
5 to 95% RH (
RH<30%/h)
Maximum wet bulb temperature = 45˚C (113˚F)
Non-operating (tape)
20 to 80% RH (
RH<30%/h)
Shock
Operating
No Data Loss
Half Sine
Performance
5 G Peak 3 ms
3 axes, 3 directions
*Interval of 10 seconds
Non-operating
No Device Damage
Half Sine
90 G Peak 3 ms
(30 G Peak 11 ms)
3 axes, 3 directions
*Interval of 10 seconds
Air-cooling Requirement
Surrounding temperature
< 40˚C (104˚F)
Clean air flow is recommended to minimize the possibility of data loss.
Power Requirements
Voltage
Max Ripple
Current
Typical
Maximum
5 V +/– 5 %
100 mVp-p
1.5 A
2.5 A
12 V +/– 10 %
150 mVp-p
0.75 A
3.0 A