KV-27S40 / 27S45 / 27S65 / 29SL40 / 29SL40A / 29SL40C/
29SL45 / 29SL65 / 29SL65C/ 29XL40M / 29XL40P / 29XT11A
A
 BOARD
The following adjustments should always be performed when
replacing the following components which are marked with 
] on
the schematic diagram:
DY, C511,C572, C573, C574, C575, D573, D574, R582, R583
R585, R586, R578, R579, T504, IC301, IC521, IC603, C507,
C508, C509, C515, C520, L591,L501
(1)
Preparation before Confirmation
Using Variac, apply AC input voltage: 120+2VAC
(or 220 + 2 VAC for KV-29SL40A/29SL40C
29SL65C/29XT11A  ONLY)
1)
Turn the POWER switch ON.
2)
Input a white signal and set the PICTURE and BRIGHT
controls to maximum.
3)
Confirm that the voltage between C574 (+) or TP503 and
ground is more than: 105VDC.
(2)
Hold-down Operation Confirmation
1)
Connect the current meter between Pin 11 of the FBT
(T504) and the PCB land where Pin 
11
 would normally
attach. (see figure 1.0 on next page)
2)
Input a dot signal and set PICTURE and BRIGHTNESS to
minimum: IABL = 100+100
µ
A
3)
Confirm the voltage of A board TP-600 is 135 
±
 3VDC
4)
Connect the Digital Voltmeter and the DC power supply
via diode 1SS119 to C574 (+).  (See figure 1.0 on next
page.)
5)
Increase the DC power voltage gradually until the picture blanks out.
6)
Turn DC power source off immediately.
7)
Read the digital voltmeter indication.
STANDARD
Less than or equal to:
141.3 VDC
8)
Input a white signal and set PICTURE and BRIGHTNESS
to maximum:   
IABL = 1750+100
µ
A
9)
Repeat steps from (4) to (7).
STANDARD
Less than or equal to:
141.3 VDC
SECTION 4
SAFETY RELATED ADJUSTMENTS
The following adjustments should always be performed
           when replacing the following components which are marked
           with 
] on the schematic diagram:
IC603, IC601, R699
1)
Using Variac, apply AC input voltage: 130 + 2.0 VAC
(or 220.0 
±
 2.0 VAC for KV-29SL40A/29SL40C/
29SL65C/29XT11A only).
2)
Input a dot signal.
3)
Set the PICTURE control and the BRIGHT control to
minimum.
4)
Set to service adjustment mode.
5)
Select PADJ with 
 and 
 .
6)
Adjust with   to the 0 level.
7)
Confirm the voltage of A BOARD TP-600 is less than
138 VDC.
8)
If step 7 is not satisfied, replace the components, repeat the
above steps.
9)
Adjust with   and 
 for:
135 
±
 3 VDC
10) Write into the memory by pressing 
 then
.
 
B+ VOLTAGE CONFIRMATION AND ADJUSTMENT
(3)
Hold-down Readjustment
If the current setting indicated in step 2-2 cannot be met,
readjustment should be performed by altering the resistance value
of R584, a component marked with 
.
+
I  ABL
ABL
T504
FBT
range
-
ammeter
3.0 mA DC
A
 R584 CONFIRMATION METHOD 
 
(HV HOLD-DOWN CONFIRMATION)  AND READJUSTMENTS
4. ba4 (2) safety adjustment