Nokia 5140 Manuales De Servicio

Descargar
Página de 84
Nokia Customer Care
System Module and User Interface
NPL-4/5
Issue 1 05/04
Copyright © 2004 Nokia Corporation. All rights reserved.
Page 39
Figure 9: Ambient Temperature Sensor Interface to BB
Backup battery
Backup battery is used in case when main battery is either removed or dis-charged. 
Backup battery is used for keeping realtime clock running for minimum of 30 minutes.
Rechargeable backup battery is connected between UEMEK VBACK and GND. In UEMEK 
backup battery charging high limit is set to 3.2V. The cut–off limit voltage (V BUCoff– ) 
for backup battery is 2.0V.
Backup battery charging is controlled by MCU by writing into UEM register. Li-Ion SMD 
battery type is used. The nominal capacity of the battery is 0.01 mAh.
Table 20: Backup Battery Circuitry
SIM interface
The UEMEK contains the SIM interface logic level shifting. The SIM interface can be pro-
grammed to support 3V and 1.8V SIM. A register in the UEMEK selects SIM supply volt-
VANA 
R211, 12k 
5% 
R212, 68k 
1% 
R101,10k 
NTC 1% 
Headint2 
AuxDet 
UI board 
UEMEk 
A/D 
MUX 
Slow
ADC 
Parameter
Test conditions
Back-up battery 
voltage
VBACK
2.43
3.3
V
V_BU
COFF+
2.04
2.1
2.16
V
V_BU
COFF-
1.94
2
2.06
V
Charging voltage 
(VBAT 3.4V)
VBU
3.1
3.2
3.3
V
Charging current
I
LIMVBU
150
500
uA
Typ
Max
Units
Back-up battery 
cut-off limit
Symbol
Min