Page 59
DC Supply Current Check
For a quick check of DC power supplies refer to the diagram below. Voltage drops are 
measured at the respective resistors pads. Note, that not all currents can be checked in 
such a way,  see the marking <na> (not applicable) in the diagram.
Figure 32: DC Power Supply Diagram
VR1 
4.78 V   [ 4.6V ... 4.9V ] 
charge pump (VCP)
Tx modulator (Vcc_ModOut)
2.81 V   [ 2.70V ... 2.86V ]
VCTCXO (+VCC)
digital interface (VDIG)
VR4 
VR3 
VR2 
PLL prescaler (VPRE)
VR5 
phasing dividers of Rx (VLO)
BB buffer (VDIG)
VR6 
Rx Front End (VRF_RX)
16 mA [max. 20 mA]
VCO (VCC_VCO)
VR7 
UEM 
Triple band PA
VBAT 
100 uA
 
bias reference (VB_EXT)
V 
refRF01
TX buffer & EDGE ALCs (VRF_TX)
Bias & Rx CH filters (VF_RX)
2.81 V    [ 2.70V ... 2.86V ]
RF controls (VPAB_VLNA)
2.81 V    [ 2.70V ... 2.86V ]
 
< na > 
V 
refRF02
2.81 V    [ 2.70V ... 2.86V ]
2.81 V    [ 2.70V ... 2.86V ]
2.81 V    [ 2.70V ... 2.86V ]
4.1 V    [ 2.95V ... 4.7V ]
1.36 V    [ 1.32V ... 1.38V ]
 
< na >
 
< na >
 
< na >
 
< na >
 
< na >
 
< na >
 
< na >
 
< na >
 
< na >
 
< na >
 
 
R511( =0R )
 
0 mV/ <4 mA
 
R500 ( =5.6R )
 
90 mV/ 16 mA
 
R525 =4.7k )
 
x mV/ y mA
 
 
 
 
 
< na >