Tuning Steps
1. RX Calibration (AGC + AFC)
Procedure
Follow the steps described in chapter ”Service Software Instructions” sec-
tion ”RX calibration... command”.
Software reports the following:
AFC init value
AFC slope
PSW slope
AGC DAC values and the corresponding voltages for each gain step (0 -
57 dB)
Limits for the reported values
If everything went well the reported values should approximately be the
following:
Parameter
Low limit
High limit
AFC init value
–80
80
AFC slope
130
230
PSW slope
250
350
AGC 0 dB
400
640
AGC 57 dB
100
300
Difference between the two neighbour
AGC steps
10
20
Troubleshooting
If the calibration does not succeed the software normally reports ”Unable
to read data from phone” or ”Failed to set high reference” or ”Failed to set
low reference”.
In this case check first the basic functionality of the receiver chain: RF
generator frequency set as in the calibration and level for example to the
high reference value.
Then go to the RSSI reading menu (under RF controls). If the reading is
very low there is something broken in the receiver and must be found by
measuring voltages and signal levels at different places (information of
these can be found elsewhere in this manual).
If the RSSI reading seems to be within 5 - 10 dB the same as the RF in-
put level check that the VCTCXO (G650) frequency is close enough the