Appendix
177
Parallel Interface Connector
Tr
oub
less
h
ootin
g
BUSY
Signal indicating that printer is unable to receive data.
Printer is able to receive data when this signal is Low.
PE
Signal indicating Paper Out of printer.
This signal is Low when paper is loaded and is High when paper is out.
SELECT
Signal indicating that printer is under online status.
Printer is capable ofreceiving data when this signal is High.
nAUTFD
Signal used for bi-directional communication.
GND
Ground
VCC
Signal indicating that the power of printer is on.
This signal allows verifying ON/OFF status of power of printer and connection status of
printer cable.
nINT
Signal for initializing printer.
Steady-state value is High.
Printer is initialized by Low.
nFAULT
Signal indicating that printer is faulty.
nSELIN
Signal used for bi-directional communication.
Signal name 