3.9 Connection of DECT Portable Stations
172
Installation Manual
Notes
The no. 4 and no. 5 pins (Master) of the CS must be connected to a pair of pins on the DHLC/DLC 
card. Then use 4 consecutive pairs of pins on the DHLC/DLC card, starting with the pins 
corresponding to the Master, as in the example above.
When connecting multiple KX-TDA0158CE CSs to a DHLC/DLC card, make sure that the no. 4 and 
no. 5 pins (Master) of adjacent CSs are at least 3 pairs of pins away on the card.
CS connections must be made within the same DHLC/DLC card.
When a wrong connection is made, satisfactory performance of the CS cannot be guaranteed. Check the connection of CS and the PBX using the KX-TDE Maintenance Console. For information about how to view CS information using the KX-TDE Maintenance Console, refer to "2.5.15 Utility—CS Information" in the PC Programming Manual. 
KX-TDA0141CE
Accessories and User-supplied Items for the CS
Accessories (included): Screws × 2, Washers × 2
User-supplied (not included): RJ11 connector
Note
For details about DHLC card or DLC card, refer to "3.6.2 DHLC8 Card (KX-TDA0170)", "3.6.3 DLC8 
Card (KX-TDA0171)
", or "3.6.4 DLC16 Card (KX-TDA0172)" .
DHLC8 Card
Cable
Maximum Distance
ø 0.4 mm:
222 m
ø 0.5 mm:
347 m
ø 0.6 mm:
500 m
CAT 5:
347 m
D1
D2
1
2
3
4
D1
D2
CS (RJ11)
Pin No.
Signal Name
Signal Name
DHLC/DLC card (Amphenol)