Panasonic KX-TGP500 Manual De Usuario
TIME_SYNC_INTVL
Value Format
Integer
Description
Specifies the interval, in seconds, to resynchronize after having
detected no reply from the NTP server.
detected no reply from the NTP server.
Value Range
10–86400
Default Value
60
TIME_QUERY_INTVL
Value Format
Integer
Description
Specifies the interval, in seconds, between synchronizations with the
NTP server.
NTP server.
Value Range
10–86400
Default Value
43200
Web User Interface Reference
4.4.6 STUN Settings
STUN_SERV_ADDR
Value Format
String
Description
Specifies the IP address or FQDN of the STUN server.
Value Range
Max. 127 characters (IP address in dotted-decimal notation or FQDN)
Default Value
Empty string
Web User Interface Reference
STUN_SERV_PORT
Value Format
Integer
Description
Specifies the port number of the STUN server.
Value Range
1–65535
Default Value
3478
Web User Interface Reference
STUN_2NDSERV_ADDR
Value Format
String
Document Version 2010.03.15
Administrator Guide
159
4.4.6 STUN Settings