This vacuum cleaner is fitted with a thermal-fuse device, that will operate when over heating occurs.
If your cleaner does not work, it is possible that the over heating device has operated. If this occurs,
take the vacuum cleaner to an official Panasonic Service Centre to be repaired.
NOTE: If the flexible power cord becomes damaged, it must be repaired by Panasonic, or an
Authorised Service Centre or a qualified person in order to avoid any hazard.
Before returning the vacuum cleaner to a Panasonic Service Centre, check the
following points:
Trouble
Check Point
Cause / Remedy
Motor fails to rotate
(no noise is heard at all).
Motor runs but no
suction.
Beater bar does not
rotate.
• Mains plug connection.
• Mains plug fuse.
• Hose inlet clogged.
• Check dust indicator.
• Paper bag broken.
• Central filter.
• Beater bar housing is clogged.
• Belt broken / loose.
• Mains plug connected firmly and
mains outlet is on.
• Check fuse and replace if blown.
• If there is a blockage, remove it.
• If shows full, replace the paper bag.
• If paper bag is broken replace it.
• If the central filter is full of dust,
clean or replace it.
• If there is any obstruction, remove it.
• If the belt is broken, replace it. If
loose re-install it again.
Design and specifications may be changed without notice.
Weight and dimensions shown are approximate.
TROUBLE SHOOTING GUIDE
SPECIFICATIONS
MC-E464
MC-E468
MC-E469
Power source
230-240V~50Hz
230-240V~50Hz
230-240V~50Hz
Max. output
1500W
1600W
1600W
Nominal output
1150-1250W
1300-1400W
1300-1400W
Dimensions (WxLxH) mm
312x310x1050
312x310x1050
312x310x1050
Net weight
6 kg
6 kg
6.1 kg
Dusting brush
Extension wand