Panasonic NE-1021T Manual De Usuario

Descargar
Página de 4
 
F81, F82, F83, 
F84  
 
 
 
These codes indicate there is no voltage supplied to the primary winding of the high 
voltage transformer. The relationship between the codes and transformers is as 
follows: 
 
F81 (PRO-1) – Upper transformer 
F81 (NE1780J, NE1780R, NE2180) – Left transformer 
F81 (NE2680J, NE2680R, NE3280) – Lower left transformer 
F82 (PRO-1) – Lower transformer 
F82 (NE2680J, NE2680R, NE3280) – Lower right transformer 
F83 (NE2680J, NE2680R, NE3280) – Upper left transformer 
F84 (NE1780J, NE1780R, NE2180) – Right transformer 
F84 (NE2680J, NE2680R, NE3280) – Upper right transformer 
 
NOTE: These codes are not caused by defective high voltage components 
(magnetrons, capacitor, diodes, and transformers. Replacing these 
components will not solve the problem. 
 
After identifying the malfunctioning circuit, perform the troubleshooting in the 
following order: 
 
a)  Check line fuses and replace if needed 
b)  Check door for proper alignment, wear and tear, and excessive movement 
c)  Check door hooks for wear and tear (it may affect the switching sequence) 
d)  Check latch switch assembly and make sure that all switches operate 
properly. Make sure they turn on and off when the door is open and closed. 
Confirm there are free of grease and debris. NOTE: Replace all switches 
even though only one may appear malfunctioning. 
e)  Troubleshoot relays (on the low voltage board) 
f)  Check controller (DPU) board for voltages necessary to actuate relays 
g)  Check controller (DPU) board for cracks, poor connections, or conductive 
residue on the component side. Clean, repair, or apply technical bulletin 
(NE1018-1757) 
h)  Replace low voltage board (only if confirmed defective) 
i) 
Replace controller (DPU) board (only if confirmed defective) 
 
 
PRO-1 
PRO-2 
 
PRO-1 
PRO-2 
 
 
F86, F87, F88, 
F89  
 
These codes indicate malfunction one of the relays (shorted contacts). The 
relationship between the models and relays is as follows: 
 
F86 – RY3 (PRO-1, PRO-2) 
F87 – RY4 (PRO-1) 
F87 – RY5 (NE2680J, NE2680R, NE3280) 
F88 – RY7 (NE2680J, NE2680R, NE3280) 
F89 – RY9 (PRO-2) 
 
a) On PRO-1apply technical bulletin (NE1018-1757) if applicable. 
 
NOTE: Before replacing the relays, make sure that the controller (DPU) board is free 
of residue or conductive substances (component side). Clean if necessary. 
 
 
PRO-1 
PRO-2 
 
No light in the 
cavity, no 
display, when 
the door is 
open 
 
a)  Line voltage (circuit breaker) 
b) Fuses 
c)  Cavity thermal cutout 
d)  Thermal cutouts on all magnetrons 
e)  Voltages on controller (DPU) board – if missing, check the low voltage 
transformer 
 
 
OCS 
PRO-1 
PRO-2