Contents 33 
 
 
 
Table 6 
 Hard drive activity LED indicator status
 
Item   LED indicator  
Status  
Description  
 
 
Flashing green during a 
drive activity (if 
command is outstanding 
continually the indicator 
is forced to flash at 4 Hz 
50% duty cycle instead 
of solid off) 
 
The drive is currently performing an I/O 
activity. 
 
The drive is a member of a RAID volume. 
 
The drive is not in a replacement or failed state 
for any volumes that it is a member of (drive is 
online). 
 
The drive is not rebuilding. 
 
The drive is not a member of a volume 
undergoing capacity expansion or RAID 
migration. 
 
 
Flashing green @ 1 Hz 
50% duty cycle (override 
drive activity output) 
 
The drive is rebuilding. 
 
The drive is a member of a volume undergoing 
capacity expansion or RAID migration. 
Drive Online/Error LED 
indicator 
Off 
 
The drive is not in a failed state. 
 
The drive is not selected (unit identification). 
  
Solid 
blue 
 
The drive is not in a failed state. 
 
The drive is selected (unit identification) 
  
Solid 
amber 
 
The drive is in a failed state. 
 
The drive is not selected. 
 
 
Flashing amber @ 1 Hz 
50% duty cycle 
 
 
Flashing amber/blue @ 
1 Hz 50% duty cycle 
 
The drive is in a predictive failure state. 
 
The drive is not in a failed state. 
 
The drive is not selected. 
 
 
The drive is in a failed or predictive failure 
state. 
 