System Features     15
Power supplies
The system supports two 400-Watt redundant power supply modules 
capable of load sharing. The standard configuration includes a single 
module. The second module can be purchased as an option and provides 
redundancy and hot-swap capabilities.
Power supply status lights
Each power supply module has a multi-color status light. 
Green indicates normal operating mode
Amber indicates standby mode
No light indicates the power supply module is not receiving power 
or has failed
Voltage selector switches
Located on the back of the power supply module, this switch must be set to 
the proper AC line voltage used in your locality (115VAC or 230VAC). If 
the optional second module is installed, there are two Voltage Selector 
Switches.
AC power-in connectors
This is a connector into the power supply that provides the electrical current 
to the system and its peripherals. Using the power cable supplied with the 
system, connect the power supply into a wall outlet. If the optional second 
module is installed, there are two AC Power-In connectors. If you use both 
modules, plug each power cable into a separate wall outlet, preferably on 
separate circuits.
 Caution!
The voltage selector 
switches are set at the 
factory. Changing them 
may result in severe 
damage to the server.