Gateway E-826R Manual De Usuario

Descargar
Página de 116
Autoloader power specifications
www.gateway.com
97
Autoloader power specifications
Temperature Variation
Operating
50
º
F (10
º
C) per hour
Nonoperating
68
º
F (20
º
C) per hour
Humidity
Operating
20% to 80% noncondensing
Nonoperating
10% to 90% noncondensing
Gradient
10% per hour without condensation
Wet Bulb
Operating
78.8
º
F (26
º
C) max
Nonoperating
84.2
º
F (29
º
C) max
Altitude
Operating
-502 ft. to 10,000 ft. (-153 m to 3048 m)
Nonoperating
-502 ft. to 40,000 ft. (-153 m to 12192 m)
Line voltage
All Drive Types
60 Hz system: 90–265 VAC;
50 Hz system: 90–265 VAC
Maximum power
All Drive Types
160 W
Line frequency
All Drive Types
47–63 Hz
AC Input current
All Drive Types
60 Hz system: 4.0 A (RMS) for 115 VAC
50 Hz system: 2.0 A (RMS) for 230 VAC
Power consumption
All Drive Types
60 Hz = 75 W; 50 Hz = 80 W