Gateway E-826R Manual De Usuario

Descargar
Página de 116
CHAPTER 5: Troubleshooting your Autoloader
www.gateway.com
82
The front panel and light indicators do 
not turn on.
Make sure that the autoloader is plugged in.
Make sure that the power switch on the back is turned on.
Make sure that the drive carrier assembly is locked into the autoloader 
chassis with the four screws supplied.
Contact Customer Care
The front panel does not display 
information, but light indicators above 
the front panel are turned on.
Connect to the autoloader, using On-board Remote Management with 
an Ethernet connection and issue a System Reset from the Diagnostics 
page.
Make sure that the drive carrier assembly is locked into the autoloader 
chassis with the four screws supplied.
On the front panel, press and hold the power switch for 15 seconds, 
then turn the rear power switch off. Wait 60 seconds and turn the rear 
power switch back on.
Contact Customer Care.
The autoloader does not communicate 
with the host system through the SCSI 
bus.
Make sure that the SCSI cables are connected to the rear of the 
autoloader and that the correct LVD host controller card is installed.
Make sure that the SCSI cables are not damaged or crimped and the 
total SCSI cable length does not exceed the maximum required length.
Make sure that a LVD SCSI terminator is attached to both the first and 
last SCSI device on the SCSI bus.
Make sure that the autoloader SCSI ID is set to a unique SCSI ID that 
is not used by any other SCSI device on the same SCSI bus.
Issue a System Reset either by using the On-board Remote 
Management Diagnostic page or by turning off power from the front 
panel.
Contact Customer Care.
The tape drive responds on the SCSI bus 
to the host, but the autoloader does not 
respond.
Make sure that the autoloader LUN is set to 1. On the front panel, 
select StatusDrive, then select Status.
Go to the Configuration menu and make sure that the mode is set to 
Random.
If the SCSI ID is unique, check SCSI cables and terminators.
Make sure that the host application and the device drivers are 
installed with the most current patches to support the autoloader.
The autoloader does not communicate 
with the host system through the 
Ethernet.
Make sure that the Ethernet cable is connected to the correct hub.
Check the Ethernet configuration settings through the front panel 
LCD. If the DHCP server is available, Ethernet status should indicate 
DHCP, otherwise, you must set a unique IP address and a subnet mask.
Power off the autoloader by turning off the system from the front 
panel LCD and turning it back on.
Contact Customer Care.
The application software reports a failure 
locating a piece of media or fails to move 
a piece of media as requested.
Use the On-board Remote Management tool and make sure that the 
media is in the expected location internal to the autoloader.
Using On-board Remote Management diagnostic tool, execute the 
Loader–Health Check command.
Issue a System Reset either by using On-board Remote Management 
Diagnostics page System Reset, or by turning the power off from the 
front panel.
Contact Customer Care.
The application software reports an error 
while reading or writing a piece of 
media.
Try a different piece of media.
Issue a System Reset either by using On-board Remote Management 
Diagnostics page System Reset, or cycle the power from the front 
panel.
Contact Customer Care.
Problem
Suggested Action