Running diagnostic tests from the front panel
www.gateway.com
67
Performing a POST
If you experience errors while operating your autoloader, you may need to 
reboot the autoloader to perform a POST.
 Caution
Whenever you power cycle the
autoloader, allow 10 seconds before
turning the power back on. The power
supply requires at least two to three
seconds for the capacitors to discharge.
This ensures a complete system reset on
power down and may avoid system
errors.
To reboot the autoloader:
 
1
Hold down the power button until “System Shutdown Please Wait...” 
appears.
2
Release the power button. The autoloader turns off.
3
Wait 10 seconds, then press the power button again to turn the autoloader 
on. POST runs automatically.
Interpreting the POST results
While the POST is running, a progress indicator showing the name of the test 
displays on the front panel. If the autoloader is working correctly, the message 
“System Ready” and the current configuration display after the POST completes 
successfully.
If the autoloader is not working correctly, error messages appear on the front 
panel (see 
).
Running diagnostic tests from the front panel
Important
On-board Remote Management lets you
request all diagnostic tests, but any tests
that require a cartridge to be inserted
times-out unless you manually insert the
cartridge at the appropriate time.
Diagnostic tests let you calibrate parts of the autoloader, check the condition 
of parts, or test the autoloader’s functionality. From the front panel, you can 
perform all of the diagnostic tests. Because certain tests require you to manually 
insert a cartridge, you can perform only some of the diagnostic tests using 
On-board Remote Management (see 
.
PLL Clock 
Tests that the microprocessor’s PLL is synchronized correctly.
LCD
Verifies that the LCD is present and working correctly.
Ethernet 
Configures and verifies communication with the Ethernet chip.
Barcode
Verifies that the bar code reader is present and performs a hardware 
handshake.
Temperature Sense
Passes/Fails the MDM and configures the AHIM temperature 
sensors.
MDM
Verifies that the MDM is present and checks the sensors.
Fan 
Verifies that the fan is operating correctly.
POST 
Test Description