Toshiba brst-10 Manual De Usuario

Descargar
Página de 28
EO1-13013
4.1 REQUIREMENTS FOR OPERATION
This printer has the following requirements:
The ECR or POS terminal must have a serial port.
To communicate with the ECR or POS terminal, an RS-232C cable is required.
RS-232C cable ................ 25 pins
Interface Cables
Use the serial printer cable CBLST-50-2-QM supplied by TOSHIBA TEC or its equivalent.
To prevent radiation and reception of electrical noise, the interface cables must meet the following
requirements:
Fully shielded and fitted with metal or metalised connector housings.
Kept as short as possible.
Should not be bundled tightly with power cords.
Should not be tied to power line conduits.
NOTE:
Use the RS-232C cable which connector securing screws are inch type.
4. SET UP PROCEDURE
4-1
Place the printer on a flat, stable surface.
Use a grounded electrical outlet.  Do not use an adapter plug.
Be sure there is adequate room around the printer for easy operation and maintenance.
Keep your work environment static free.
Controller side
D-SUB 9-pin female
Printer side
D-SUB 25-pin male
PIN-No
Case
2
3
8
4
5
6
Signal
FG
RXD
TXD
CTS
DTR
GND
DSR
PIN-No
1
2
3
4
6
7
20
Signal
FG
TXD
RXD
RTS
DSR
SG
DTR