 62 − 
 
6 F 8 A 0 9 3 4  
For example, if the setting range is 10m/s and display digit setting is 1/100, the measured value will 
be displayed to the first decimal place. 
 
 
         Setting range=10.0000  m/s 
 
 
 
 
 
Likewise, when the setting range 1m/s and display digit setting is 1/100, the measured value will be 
displayed to the second decimal place. 
The numbers less than the displayed digits will be rounded. 
 
Note: The maximum display digits for flow velocity, flow rate and custom value are 7 digits. 
If the measured value exceeds 7 digits, the displayed value remains fixed at the maximum display 
value. 
 
 
● Changing the totalized flow volume direction   
You can change the totalized flow volume direction as described below. 
 
The following is an example to change the Display 1 setting from Fixed forward totalized flow (F) 
to Bidirectional flow (B). 
 
Switch operation 
Display example 
Description 
 
DSPL1 
 
   m
3
      F 
 
 
 
 
 
Select "DSPL1" from the setting item 
selection menu. 
The currently set display setting (m
3
  F
 in 
this example) appears. 
Then push              . 
STEP1 
 
 
 
DSPL1 
 
   
m
3
      F 
 
 
 
 
The switches at the bottom change. 
(                                      are shown.) 
 
At the same time, the cursor appears. 
 
 
STEP2 
 
 
 
DSPL1 
 
   m
3
      
B
  
 
 
 
 
Push                to  move  the  cursor  to  the 
third unit (totalized flow direction) and then 
push       to change the direction. 
 
Then push      to set the display unit 
temporarily. 
STEP3(=END) 
 
 
 
DSPL1 
 
   m
3
      B 
 
 
SET OK?
 
 
 
Pushing       shows a message to confirm 
whether the setting is OK or not. 
If OK, push       . If you need to redo the 
setting, push      . 
Pushing      cancel the setting operation 
and exits the setting screen. 
 
 
Maximum effective digits 
One hundredth of 
maximum effective digits
ESC 
N O
O K
ESC 
O K
N O
ESC