3.  Tests and Diagnostics 
Satellite A205/A200 /Satellite Pro A200/EQUIUM A200/ SATEGO A200 Series Maintenance Manual  3-19 
3.12 Magnetic Switch Test 
The lid switch test checks the lid function of the unit. When LCD cover closed, the lid should 
enable to turn off the display. 
NOTE:  Remember to tune up the volume as “Maximum” before this test starts. 
 
Follow below steps to run this test:  
1.  Close the LCD cover. 
2.  Heard 3 “Beep” sound happened during LCD closed. 
3.  Open the LCD. 