Toshiba scale view v3 Manual De Usuario

Descargar
Página de 22
Scale View Owner’s Manual
Error Messages
- 15 -
ERROR MESSAGES
Mismatch Data Length
TMCC text file format is incorrect – check Scale Table 
file format version against setting in scale (Initial set 9 
bit 7: 1 = Version 2.3; 2 = Version 2.8). Refer to Scale 
Table settings and Initial Set Information.
SL9000DRV.EXE is not found
This  is  the  TMCC  driver  (SL9000DRV.EXE).  This 
error will display when running the Scale View for the 
first time. Start Windows Explorer, go to “c:\program 
files\scaleview\” and double click on the driver icon. A 
new window will open, click on File in new window 
and then on Exit. This registers the driver in Windows. 
This error occurs with Demo CD and some Windows 
versions, like Windows XP. 
Terminal Busy
The master scale is in the middle of LON command or 
in the middle of reset. If this is not the case, status clear 
scale in question.
Invalid Port Number
The COM port selected for the PC in the Scale Table 
doesn’t exist. Select another COM port.
Cannot Open Port
The COM port selected in the Scale Table for the PC 
is  malfunctioning,  currently  being  used  by  another 
program,  or  another  application  did  not  release/close 
the COM port after usage. Try re-booting PC, or select 
another COM port.
Error Closing Port
The COM port selected in the Scale Table for the PC is 
malfunctioning or is currently being used by another 
program. Select another COM port.
Select Failed in Command Sequence
The  selected  scale  is  not  responding  -  check  scales 
Initial sets and “Online” status, Scale View Scale Table 
configuration, cabling or Level Converter. 
Poll Failed in Get Data Sequence
Selected scale stopped communicating. Check cabling, 
Level  Converter,  scales  Initial  sets,  and  Scale  View 
Scale Table configuration. 
Poll Failed in Command Sequence
PC stopped communicating with scale. Check cabling, 
Level  Converter,  scales  Initial  sets,  and  Scale  View 
Scale Table configuration.
Expected Ack: Send Command
Check cabling, Level Converter, scales Initial sets, and 
Scale  View  Scale  Table  configuration.  May  see  this 
with USB to RS-232 adapter, which is not supported.
Expected Ack: Send Message
Check cabling, Level Converter, scales Initial set, and 
Scale View Scale Table configuration.