Error Messages 
Scale View V4.0 Owner’s Manual
 
Page  32 
18-Oct-04
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
“Run Time error 76” 
when trying to access 
TMCC log 
The file “notepad.exe” is not found in the default 
directory. The default directory for Scale View for 
“notepad.exe” is “C:\Windows”. This error usually 
occurs with Windows NT, Windows NT WS and 
Windows NT 2000. 
 
To correct this first confirm that there is not a 
“Windows” subdirectory. If there is no “Windows” 
subdirectory you must create one and copy the file 
“notepad.exe” into it. This should take care of this 
error. 
An error occurs when 
requesting a report 
“Unable to connect, incorrect session parameters.” 
Or Microsoft Access opens and requests a 
password. 
These problems occur because of a conflict between 
different versions of Crystal Reports installed by 
other programs. 
Contact your TEC Representative for assistance. 
Scale Not 
Communicating 
In Scale View V4.0 this error indicates that there is a 
problem with a Scale’s IP address. This problem 
could be that it isn’t programmed in the scale or in 
Scale View’s Scale Table correctly. Check the Scale 
View Scale Table configuration and the Scale’s IP 
address.