LOOPING OUTPUTS 
 
The 8 and 16 Channel DVR units may have up to 16 Looping outputs. Depending on the destination of the outputs, each output may 
have to be terminated.  Looping outputs for a 16 Channel DVR looping are highlighted below. 
32 Channel EVR units may have up to 32 looping outputs. 
 
 
 
 
 
 
 
The Video inputs are RJ-59 BNC connectors. Make sure there is a video source connected to the input and then connect a cable to 
the Channel Out. The looping outs can be connected to video monitors or combined with adapters to connect to VCR’s.     
 
 
LOOPING OUTPUT TERMINATION 
 
When terminating the outputs becomes necessary, the DVR unit has built in termination that allows you to select individual outputs to 
terminate individually. It is not always necessary to terminate the output when using it. It is dependant on the device with which you 
are connecting it to. As a rule, if the image appears distorted or virtually unviewable, it most likely needs to be terminated.   
 
 
Always leave the dipswitch set to the ON position when the Looping Outputs are not used. 
 
ON 
Not connected to a monitor (Normal) 
OFF 
Connected to a monitor (Looped)