kymco mo zx50 Manuales De Servicio
16
. INSTRUMENT/SWITCHES/LIGHTS
16-3
ZX / SCOUT 50
INSTALLATION
The installation sequence is the reverse of
The installation sequence is the reverse of
removal.
OIL METER
INSPECTION
Remove the met-in box. (12-4)
Remove the met-in box. (12-4)
Remove the frame body cover. (12-4)
Disconnect the oil meter wire connectors
and remove the oil meter. Keep the oil
meter float at the lower position.
Measure the resistances between the wire
terminals as and shown in the left
figure.
Wire Terminals
Resistance
Green/Red(+)_
Black(-)
5_
16Ω
Green(-)_
Black(+)
∞
Oil Meter Operation Inspection
Connect the oil meter wire connectors and
Connect the oil meter wire connectors and
turn the ignition switch ON.
Measure the resistance between the wire
terminals with the float at upper position.
Green/Red(+)_
Black(-) About 340Ω
Light OFF
Light ON
Retainer
G
G
Float
G/R
B
B
Oil Meter
4.5± 1.0m
m