7. ENGINE REMOVAL/INSTALLATION
7-3
XCITING 500
Disconnect the water temperature sensor
connector.
Disconnect AICV air supply hose from the
AICV check valve.
Disconnect the spark plug cap from the
cylinder head.
Disconnect the crankcase breather hose form
the cylinder head cover.
Release the rubber cap and remove the
terminal nut to disconnect the starter motor
cable.
AICV air Supply Hose
Water Temperature Sensor Connector
             Rubber Cap
          Nut
Crankcase Breather Hose