Details on libraries and scene memory
8
Using libr
ar
ies and scene memor
ies
79
AW1600  Owner’s Manual
Repeatedly press the Quick Loop Sampler section [SAM-
PLE EDIT] key or hold down the [SAMPLE EDIT] key 
and use the CURSOR [
]/[
] keys to access the 
LIBRARY page of the SAMPLE screen.
SORT field
Use these three buttons to specify how the library data in 
the list will be sorted. You can choose NAME (sort alpha-
betically), OLD (sort by save date), or SIZE (sort by size).
B
LISTEN button
If you move the cursor to this button, press the [ENTER] 
key, and then press a pad, the sample assigned to sample 
bank A of the library will play.
C
DELETE button
Deletes the selected library data from the hard disk.
D
PROTECT button
When you move the cursor to this button and press the 
[ENTER] key, the Protect setting will be switched on/off 
for the library data selected in the list. Library data for 
which Protect is turned on is indicated by a “lock” icon, 
and cannot be edited or deleted.
E
NEW button
Creates new library data on the hard disk.
This library contains mix parameter settings that can be 
loaded into a channel. It is convenient to use this library 
when you want to use the settings of a specific channel for 
another channel. Library numbers 00–01 are read-only 
data for initializing a channel, and 02–64 can be written.
Channel library data contains the following parameters.
• Channel on/off
• Attenuator
• EQ on/off
• EQ parameter settings
• Dynamics processor on/off
• Dynamics processor parameter settings
• Fader position
• Aux buses 1/2 pre-fader/post-fader setting
• Send levels to Aux buses 1/2
• Effect buses 1/2 pre-fader/post-fader setting
• Send levels to effect buses 1/2
Repeatedly press the Selected Channel section [VIEW] 
key or hold down the [VIEW] key and use the CURSOR 
[
]/[
] keys to access the CH LIB page of the VIEW 
screen.
Scene memories recall the effect parameter and mix 
parameter settings of all channels.
Scene number 00 is read-only data used to initialize the 
current scene. Scene numbers 01–96 are writable data.
In the data entry/control section, repeatedly press the 
[SCENE] key or hold down the [SCENE] key and use the 
CURSOR [
]/[
] keys to access the LIBRARY page of 
the SCENE screen.
PROTECT button
When you move the cursor to this button and press the 
[ENTER] key, the Protect setting will be switched on/off 
for the scene selected in the list. Scene data for which Pro-
tect is turned on is indicated by a “lock” icon, and cannot 
be edited or deleted.
■ Recalling sample library data
4
5
1
3
2
Channel library
■ Recalling channel library data
• Data for parameters that do not exist in the recall-destination 
channel will be ignored.
• If the recall-destination is the stereo output channel or a paired 
channel, the parameters will be the same for the L and R chan-
nels, with the exception of Phase and Pan (phase and pan set-
tings will not change).
HINT
Scene memories
■ Recalling a scene memory
1