Siemens TC63 Manual De Usuario
![Siemens](https://files.manualsbrain.com/attachments/fea10bc852adcb1f4f76708d5daebca542e532b9/common/fit/150/50/c53f5738b57089fc3d6c279e23db7450685a19c9616727fc1f659077967b/brand_logo.png)
TC63 AT Command Set
11.8 AT+CGEQREQ
s
TC63_ATC_V00.490
Page 284 of 501
5/24/05
Confidential / Draft - Do not copy
0
conversational
1
streaming
2
interactive
3
background
[4]
subscribed value
This parameter indicates the maximum number of kbits/s delivered to UMTS (up-link traffic) at a SAP. As an
example a bitrate of 32kbit/s would be specified as 32 (e.g.
=...,32,...).
[0]
subscribed value
1...63
64...128
64...128
(value needs to be divisible by 8 without remainder)
256
512
512
This parameter indicates the maximum number of kbits/s delivered by UMTS (down-link traffic) at a SAP. As an
example a bitrate of 32kbit/s would be specified as 32 (e.g.
=...,32,...).
[0]
subscribed value
1...63
64...256
64...256
(value needs to be divisible by 8 without remainder)
512
This parameter indicates the guaranteed number of kbits/s delivered to UMTS (up-link traffic) at a SAP (provided
that there is data to deliver). As an example a bitrate of 32kbit/s would be specified as 32 (e.g.
=...,32,...).
[0]
subscribed value
1...63
64...128
64...128
(value needs to be divisible by 8 without remainder)
This parameter indicates the guaranteed number of kbits/s delivered by UMTS (down-link traffic) at a SAP (pro-
vided that there is data to deliver). As an example a bitrate of 32kbit/s would be specified as 32 (e.g.
=...,32,...).
[0]
subscribed value
1...63
64...256
64...256
(value needs to be divisible by 8 without remainder)
This parameter indicates whether the UMTS bearer shall provide in-sequence SDU delivery or not.
0
0
no
1
yes
[2]
subscribed value
<Traffic class>
(num)
<Maximum bitrate UL>
(num)
<Maximum bitrate DL>
(num)
<Guaranteed bitrate UL>
(num)
<Guaranteed bitrate DL>
(num)
<Delivery order>