Native mixer elements Sample Buffer Size 
 
 
Clicking this item calls up a dialog box which can be used to set the Sample Buffer Size for native 
mixer elements: 
 
 
 
 
 
 
 
 
The default buffer size for native mixer elements is 128 samples. Typically, it should be raised if 
the PC is struggling to cope with the processing demands. Multiples of 64 up to 1024 can be used. 
If an invalid value is entered, the closest valid value below it will be used instead. 
 
Connect to Console Manager 
 
 
Clicking this item connects the SSL Soundscape Mixer to the optional Console Manager 
application which can be used to control the Mixer from a hardware control surface and to 
automate it. The “Mixer selection” parameter of Console Manager must be set to “First 
Connecting” or “Mixtreme”. If Console Manager is not already active it will be launched 
automatically. 
 
NOTE:  Console  Manager  is  available  from  the  Solid  State  Logic  website  and  must  be  installed 
separately. 
 
Enable Mixer Automation 
 
 
 
Clicking this item enables automation for the SSL Soundscape Mixer. It is equivalent to clicking the 
Automation button in the Toolbar. Automation can only be enabled if the SSL Soundscape Mixer is 
connected to the Console Manager program. When Automation is active, the SSL Soundscape 
Mixer transmits data to Console Manager whenever an automatable mixer control is used and 
responds to automation data received from Console Manager. Most mixer controls can be 
automated, with a few exceptions for some third party plug-ins.