SMC Networks sunny mini central smc 6000a Manual De Usuario

Descargar
Página de 96
SMA 
Technologie AG
Electrical Connection 
Installation Guide
SMC50A_60A-IEN073320
Page 27
6.3 Connection of the DC Input
6.3.1 Requirements
For connecting the DC input, the following requirements must be satisfied:
1.
The connected strings must consist of modules of the same type and number and
should have an identical orientation and tilt.
2.
The connecting wires of the solar modules must be equipped with plug connectors
to allow the eight DC plug connectors of the Sunny Mini Central to be connected
to it.
A pre-assembled set for connecting the free cable ends from a string is available
as an optional accessory from SMA:
3.
Make sure that the following limit values at the DC input of the Sunny Mini Central
are not exceeded:
4.
Check the system design and the string size using the design program Sunny
Design which is available to download free at 
Connection set
Order code
Maximum 
flow current
Multi-Contact 3 mm
SWR-MC
21.0 A
Multi-Contact 4 mm
MC-SET
30.0 A
Tyco
TYCO-SET
30.0 A
Device
Maximum 
input voltage
Maximum 
input current
SMC 5000A
600 V (DC)
26.0 A (DC)
SMC 6000A
600 V (DC)
26.0 A (DC)