Gas Requirements
Natural Gas and Liquefied Petroleum
IMPORTANT: Any product revisions or 
conversions must be made by the Manufacturer’s 
Authorized Dealers, Distributors, or local service 
personnel.
IMPORTANT: The tumbler must be isolated from 
the gas supply piping system by closing its 
individual manual shut-off valve during any 
pressure testing of the gas supply piping system at 
test pressure equal to or less than 3.45 kPa, 
34.5 mbar (0.5 psi).
IMPORTANT: The tumbler and its manually 
operated appliance gas valve must be disconnected 
from the gas supply piping system during any 
pressure testing of that system at test pressures in 
excess of 3.45 kPa, 34.5 mbar (0.5 psi).
IMPORTANT: The installation must comply with 
local codes.
NOTE: This manual is only a supplement. Refer to 
installation/operation manual for full instructions.
European Gas
General Information
This information is to be used when installing gas 
tumblers in countries, and/or on gases, different than 
the machine’s factory configuration. Tumblers are 
supplied from the factory for operation on Natural Gas 
or L.P. Gas in the countries of GB/IE/PT/ES/IT/GR/
LU/CH. To install machines in any other country, or 
on any other gas, requires some level of modification.
Models are built in two different configurations:
Regulated Natural Gas – Burner orifice is sized 
for Natural Gas, second family, group H (E) at 
20 mbar inlet pressure. Regulator/governor is 
operational. Gas valve CAN be field-converted to 
a non-regulating type.
Unregulated Liquefied Petroleum (L.P.) Gas – 
Burner orifice is sized for L.P., third family, 
group 3+ at 28.37 mbar inlet pressure. Regulator/
governor is blocked open. Gas valve CANNOT 
be field-converted to a regulating type.
Serial plates supplied from the factory are configured 
for the countries of GB/IE/PT/ES/IT/GR/LU/CH. 
These instructions pertain to the situations when the 
country of use or gas supply is different than that on 
the serial plate.
NOTE: This manual is only a supplement. Refer to 
installation/operation manual for full instructions.
To reduce the risk of fire or explosion, DO 
NOT CONNECT THE GAS LINE TO THE 
TUMBLER IF THE GAS SERVICE IS NOT 
THE SAME AS THAT SPECIFIED ON THE 
TUMBLER SERIAL PLATE! It will first be 
necessary to convert the gas burner 
orifice and gas valve. Appropriate 
conversion kits are available.
W060
WARNING
To reduce the risk of fire or explosion, if 
the tumbler is to be connected to 
Liquefied Petroleum (L.P.) gas, a vent to 
the outdoors must be provided in the 
room where the tumbler is installed.
W062
WARNING
WARNING
To reduce the risk of electric shock, fire, 
explosion, serious injury or death:
• Disconnect electric power to the 
tumbler before servicing.
• Close gas shut-off valve to gas tumbler 
before servicing.
• Close steam valve to steam tumbler 
before servicing.
• Never start the tumbler with any guards/
panels removed.
• Whenever ground wires are removed 
during servicing, these ground wires 
must be reconnected to ensure that the 
tumbler is properly grounded.
W002